Opm::EclHysteresisConfig Class Reference Specifies the configuration used by the ECL kr/pC hysteresis code. More...
Detailed DescriptionSpecifies the configuration used by the ECL kr/pC hysteresis code. Constructor & Destructor Documentation◆ EclHysteresisConfig()
Member Function Documentation◆ curvatureCapPrs()
Curvature parameter used for capillary pressure hysteresis. default: 0.1 Referenced by Opm::EclHysteresisTwoPhaseLawParams< EffLawT >::finalize(). ◆ enableHysteresis()
Returns whether hysteresis is enabled. Referenced by Opm::EclHysteresisTwoPhaseLawParams< EffLawT >::setDrainageParams(). ◆ krHysteresisModel()
Return the type of the hysteresis model which is used for relative permeability. -1: relperm hysteresis is disabled 0/1: use the Carlson model for relative permeability hysteresis 2/3: use the Killough model for relative permeability hysteresis Referenced by Opm::EclHysteresisTwoPhaseLawParams< EffLawT >::setDrainageParams(). ◆ modParamTrapped()
Regularisation parameter used for Killough model. default: 0.1 ◆ pcHysteresisModel()
Return the type of the hysteresis model which is used for capillary pressure. -1: capillary pressure hysteresis is disabled 0: use the Killough model for capillary pressure hysteresis Referenced by Opm::EclHysteresisTwoPhaseLawParams< EffLawT >::setDrainageParams(). ◆ setEnableHysteresis()
Specify whether hysteresis is enabled or not. ◆ setKrHysteresisModel()
Set the type of the hysteresis model which is used for relative permeability. -1: relperm hysteresis is disabled 0: use the Carlson model for relative permeability hysteresis of the non-wetting phase and the drainage curve for the relperm of the wetting phase 1: use the Carlson model for relative permeability hysteresis of the non-wetting phase and the imbibition curve for the relperm of the wetting phase 2: use the Killough model for relative permeability hysteresis of the non-wetting phase and the drainage curve for the relperm of the wetting phase 3: use the Killough model for relative permeability hysteresis of the non-wetting phase and the imbibition curve for the relperm of the wetting phase ◆ setPcHysteresisModel()
Set the type of the hysteresis model which is used for capillary pressure. -1: capillary pressure hysteresis is disabled 0: use the Killough model for capillary pressure hysteresis The documentation for this class was generated from the following file: |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||