| bool | keepsProductionControl (const bool field_or_none, const bool targeted, const bool gas_lift_group, const bool rc_master_hierarchy, const std::optional< ReservoirCoupling::GrupSlav::FilterFlag > master_target_filter) |
| |
◆ keepsProductionControl()
| bool Opm::GroupStateHelpers::keepsProductionControl |
( |
const bool |
field_or_none, |
|
|
const bool |
targeted, |
|
|
const bool |
gas_lift_group, |
|
|
const bool |
rc_master_hierarchy, |
|
|
const std::optional< ReservoirCoupling::GrupSlav::FilterFlag > |
master_target_filter |
|
) |
| |
|
inline |
Whether a production group keeps its control mode when the groups without active constraints are set to NONE at the end of a time step.
- Parameters
-
| field_or_none | The production control mode of the group is NONE or FLD, so there is nothing to reset. |
| targeted | A well under group control has the group as its target. |
| gas_lift_group | The group is in the gas lift optimization, which needs a control mode other than NONE and FLD. |
| rc_master_hierarchy | The group is a reservoir coupling master group or one of its ancestors, which distribute targets to the slaves. |
| master_target_filter | Set when the group is a reservoir coupling slave group with a target from the master: the GRUPSLAV flag for that target. The master sends the target in the first time step of a sync step only, and the control mode it gives the group (not for SLAV, where the slave's own limit is the one used) has to survive the time steps after it. Not set when the group has no target from a master. |
|